Sheet 1 — Dimensioned Plan (to scale)
- Closure checks: 180½ + 173⅜ = 353⅞ = 302¼ + 51⅝ ✓ · 190¼ + 51⅞ = 242⅛ ≈ 242 ✓
- The far-left outer edge was taped at 97½″; the reconciled drawing closes at 99⅜″ (51⅞ + 47½). The 1⅞″ difference is absorbed there — every other written dimension is honored exactly.
Sheet 2 — Tile Layout with Perimeter Ramp (12″ grid, computed)
Beveled ramp edging, 2″ deep (9⁄16″ → 0)
Full tile (uncut)
Cut piece
- The 2″ beveled ramp runs around the entire outline — the tile field is the deck inset 2″ on every side, so the assembly finishes flush with the deck edge and ramps from the 9⁄16″ tile height down to the surface.
- Six outside corners take the 2″ × 2″ beveled corner pieces; at the two inside corners (corridor junctions) the strips simply butt together.
- Grid anchored top-right of the main field; cuts fall on the far and bottom rows. Because the field is 176½″ × 238″ (not a 12″ multiple), a ~8½″ cut column and ~10″ cut row are unavoidable — still full-size pieces, one per donor tile.
Calculation B — Tile Count & Cut Schedule
Cut pieces (grouped, with donor-tile yield)
Calculation C — Order & Cost
Perimeter edging (required — full outline)
Complete order